Metal is way better than flex duct or ductboard. It gets better airflow, holds up to critters and duct cleaners. I know of no hvac company here that cleans ductwork. (there probably is one somewhere) The mfg's of duct cleaning equipment keep trying to sell us hvac people on their benefits and profit potential but most all hvac people know that unless you have metal ductwork you are NOT doing the customer any favors.
If there is stuff in the ducts, the fact that it’s laying there and not being blown into the rooms is proof positive that it is hurting no-one. The 5-6 exceptions you cite in this article I’ll buy, but only with the caveat that at least some of those could have been avoided by proper protection (during remodeling for example) – and if asbestos/lead/whatever winds up in your ducts- the remodeling contractor should be the one paying to remove it.
I live in a 1950's ranch house in the South. The prior owners were smokers. Based on recommendations from one of the local conservation organizations, I decided to have a home energy audit done. As part of their findings, they recommended additional insulation in the attic and duct cleaning and sealing. This turned out to be a very problematic process. In terms of the ducts, it was necessary to remove the metal grates. However, these grates had been painted over many times and shoe molding covered the bottom of the grates. The vendor was not able to remove the grates without damaging them in the process. Because these grates dated back to the 1950's, it was difficult to find appropriate replacements. The ones I finally discovered were correct except they were 1/4" wider. This meant that the shoe molding had to be carved out. The duct cleaner could not provide any assistance with this problem. It took me a month of long evenings replacing the vent covers myself, carefully chiseling out the shoe molding and repainting. In terms of the extra installation in the attic, the same vendor used blow in insulation. Unfortunately, they did not recognize that the 13 floodlights whose mounting extended into the attic were not designed to be buried under insulation. The problem manifested itself in terms of expensive flood light bulbs failing continually. So, I had to have all of the light housings replaced. Yet another unexpected expense. Despite the expense, pain and suffering, I cannot report any improvement in my heating costs or the "quality" of the air. To be fair, I do not have any allergies and did not undertake this for air quality improvements but rather heating efficiency improvements.

Air duct cleaning service providers may tell you that they need to apply a chemical biocide to the inside of your ducts to kill bacteria (germs) and fungi (mold), and prevent future biological growth. Some duct cleaning service providers may propose to introduce ozone to kill biological contaminants. Ozone is a highly reactive gas that is regulated in the outside air as a lung irritant. However, there remains considerable controversy over the necessity and wisdom of introducing chemical biocides or ozone into the duct work.


We hope you found this article on a fair HVAC installation cost helpful. In the end, you’ll be alright so don’t worry too much. Do your research on reputable air conditioning contractors in your area, and spend time making sure that you have a company that you can trust – it will cost you less in the long-run, trust me. Take your time, follow the tips above, and you will end up with an HVAC installation cost that is more than reasonable, keeping your family comfortable for years to come. For more on topics like this, see: ASM’s Air Conditioning Blog.
Here in Atlanta we get 6 to 10 $49 coupons in the mail weekly…I have always consider them a complete scam….just had my master bathroom& bedroom and guest bath completely remodeled down to the studs…Had my 3 returns nearest the area sealed to prevent sheet rock dust to spread…it worked and I personally cleaned all 7 returns when a 5 HP , new Rigid shop Vac($99 from HD)…took one hour and I found little evidence that “I need my ducts cleaned” Had quotes from $400 to $600…I use the best air filters for my air handler and change it every 2 to 3 months…..any dust is trapped in it and I believe the Air Duct folks are all cons….
You may consider having your air ducts cleaned simply because it seems logical that air ducts will get dirty over time and should be occasionally cleaned. Provided that the cleaning is done properly, no evidence suggests that such cleaning would be detrimental. EPA does not recommend that the air ducts be cleaned routinely, but only as needed. EPA does, however, recommend that if you have a fuel burning furnace, stove or fireplace, they be inspected for proper functioning and serviced before each heating season to protect against carbon monoxide poisoning.

I to had an odd layer of white'ish dust building up especially during seasonal periods when the HVAC ran a a lot. I carefully swept up the fine dust into a small pile and had it analyzed. Turns out it was very fine fiberglass powder dust. It turns out it is the insulation form the attic! (My attic has blown in insulation). Turns out if you (I) had small gaps around my HVAC registers in the ceiling whee the airs blows into the room. What occurred in my case was that the exiting air at that seam creates a vacuum effect at the grate vent cover and draws and then blows fine insulation dust from the attic into the house. Removing each register grate and sealing each tin outlet gap with calking between the dry wall ceiling and tin fixed the issue. A couple were so bad with bowed gaps I had to screw down the bowed tin to the attaching stud better. Checking the very same glass top desk that catches and shows any dust accumulation now shows only very small amounts of normal house dust build up over several weeks. A big, big improvement. You might have a look by simply removing a couple vent covers yourself.
An example of a geothermal heat pump that uses a body of water as the heat sink, is the system used by the Trump International Hotel and Tower in Chicago, Illinois. This building is situated on the Chicago River, and uses cold river water by pumping it into a recirculating cooling system, where heat exchangers transfer heat from the building into the water, and then the now-warmed water is pumped back into the Chicago River.[24]
Roof-mounted systems have the heating and cooling systems in one cabinet. Sometimes called "gas packs" (if the heater uses natural gas), they typically cost less than a comparable split system. In dry regions, most homes originally had "swamp-coolers" installed. When replacing them with HVAC systems, it's often cheaper to use existing mounts and ducting.

In some older homes, there was a grey Mylar flexible duct. After years of use, it started to decompose. A duct cleaning company can come out and find why your air is so dirty and why your building doesn’t heat or cool like it used to. This is a savings on your part. You could also be sucking in Hot, dirty attic air. However, sometimes when a duct cleaning company comes out to clean it, the old duct can be destroyed and have to be replaced. Someone with little experience can replace this ductwork but if it isn’t done right it can ruin a lot of things and cost a lot in repairs.

I had my ducts somewhat cleaned December 22, 2014. The hose of the machine the technitian used did not fit in some of my vents, therefore, he did not clean them. But I still paid $428.00 for the service. I will be calling the company on Monday, and kindly ask them to come back and clean the ducts they did not as they did not fullfill their part of the service.
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it's tight. If it's not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you've swapped all the wires, secure the new capacitor (Photo 5).
×